A window certificate is useful when you can connect it to the product in your drawings. For an Ontario home, begin with three questions: who issued the document, which exact component it covers and how its data will be used in the project. Keep the certificate beside the opening schedule and proposed specification, so a familiar product name does not hide a different configuration.

Sources reviewed

Match the record to the proposed window.

This checklist helps homeowners and specifiers ask for the right records before an order is approved.

Separate the product from the building

The Passive House Institute, or PHI, certifies components and also operates building-certification standards. A component certificate supplies evidence about that component under stated conditions. Installing it does not, by itself, certify a house. PHI’s building criteria address the building as a whole, including its envelope, airtightness and building services. See PHI’s building-certification guidance.

Phius has its own window and door certification program. Its product data support calculations for the actual sizes and configurations in a project. A Phius product certificate and a PHI component certificate are different records: name the issuer and intended project standard whenever you request one. Phius also distinguishes its product climate recommendations from project approval; a recommendation does not guarantee suitability for an individual project. Read the Phius certification protocol, version 1.2, sections 1–2 and Appendix I.

If formal building certification is a goal, involve the project’s designer and certifier while specifications can still be coordinated. For a replacement project without that goal, the documents can still help you understand what a performance statement actually describes.

Read the identifying fields first

Work through the certificate before focusing on its headline number.

Read each field alongside the proposed specification.
FieldWhat to check against the proposal
Issuer and recordPHI or Phius; component/product ID and official database entry
Product nameExact model and suffix, rather than the family name alone
Category and operationFixed, operable or another stated category; matching opening type
Climate labelThe issuer’s named zone and the project team’s applicable climate basis
ValidityExpiry or current status, plus any newer certificate or revision
Glass and frameSpecified glazing, spacer, frame sections and stated restrictions
Reference geometrySize, arrangement and configuration used for the published result
InstallationWall assembly and junction details behind an installed value

Save the complete document, including explanatory pages. If a brochure, database listing and PDF disagree, ask the supplier for clarification and the current issuer record before relying on the claim. Record when you checked it.

Keep the Innotech models distinct

Innotech’s product page links separate PHI certificates for Defender 88PH+ Pro and XI fixed and operable windows. The table records the documents checked on November 7, 2026. Those copies each stated validity through December 31, 2026; this historical record does not establish their status on a later date. Recheck the issuer records when specifying and ordering. Find the manufacturer’s certificate links.

Documents checked November 7, 2026: model, category and climate labels as recorded then.
Manufacturer-linked PHI certificateComponent IDCertificate categoryClimate label
Defender 88PH+ Pro, fixed1730fx03Fixed windowCool, temperate
Defender 88PH+ Pro, T&T Window1756wi03Window FrameCool, temperate
Defender 88PH+ XI, fixed1702fx02Fixed windowCold
Defender 88PH+ XI, operable1912wi02Window FrameCold

These labels describe the listed components. Ask your project team which record applies to each opening. Keep the category, component ID and climate label together when sharing an extract; an efficiency class or climate description should stay attached to its specific record.

Distinguish Uw, Ug and installed performance

Uw describes whole-window thermal transmittance. Ug describes the glazing. The frame and glass-edge effects also contribute to the window result, so a glazing value cannot stand in for a whole-window value. An installed result additionally considers the window-to-wall junction. PHI’s transparent-component criteria distinguish these calculations. See PHI’s criteria, section 3.6.

Check the reference size and glazing used for a published result. For example, the XI fixed certificate explains its calculation basis on page 2 and lists validated installation situations on page 3. Those details give your designer something to compare with the proposed opening and wall assembly. Read the complete XI fixed certificate.

Phius certificates label center-of-glass data as U-COG and provide component data for actual-size modelling. Preserve the units, calculation method and climate conditions with any value; ask the modeller which inputs the project requires. See Phius’s window-certification guidance.

Carry the evidence into the order

Ask the supplier to identify the certificate and supporting drawing for every proposed configuration. Have the designer review the selected glass, opening sizes and installation junctions. Agree who will check that the delivered products and site details match the approved specification, and who will review substitutions.

Before approval, confirm:

  • The issuer, exact model, operation and component ID match.
  • The complete certificate and current status have been checked.
  • Glazing and whole-window values remain clearly labelled.
  • The project team has reviewed climate, geometry and installation assumptions.
  • Any substitution returns to the responsible reviewer before ordering.

Bring your opening schedule and certification goal to Haven’s Passive House window discussion. Use the technical library to organize the supporting records, and the performance page to frame the questions you want the project team to resolve.

Source documents

Use the document for the proposed system and configuration when confirming a specification.

  1. PHI: Building Certification

    Building-level criteria, distinct from a component certificate; no project certification is implied.

  2. Phius: Window and Door Certification Protocol, version 1.2

    April 15, 2026 protocol: actual-size data, separate product records and limits of product climate recommendations.

  3. Innotech: Defender 88PH+ Windows

    Manufacturer links to four separate PHI certificate records, checked November 7, 2026.

  4. PHI certificate: Defender 88PH+ Pro fixed

    1730fx03: fixed window, cool, temperate. The checked copy stated validity through December 31, 2026; recheck the issuer record.

  5. PHI certificate: Defender 88PH+ Pro T&T Window

    1756wi03: Window Frame, cool, temperate. The checked copy stated validity through December 31, 2026; no efficiency class is asserted here.

  6. PHI certificate: Defender 88PH+ XI fixed

    1702fx02: fixed window, cold. The checked copy stated validity through December 31, 2026; pages 2–3 explain calculation and installation context.

  7. PHI certificate: Defender 88PH+ XI operable

    1912wi02: Window Frame, cold. The checked copy stated validity through December 31, 2026; keep the operable record separate from fixed.

  8. PHI: Transparent Component Certification Criteria

    Version 5.6, April 1, 2025, sections 3.6 and 3.8: glazing, whole-window and installed thermal-transmittance context.

  9. Phius: Certify Your Windows and Doors

    General component-data and modelling guidance. No current Innotech-specific Phius status is asserted.

Your next step

Bring the opening schedule and certification goal.

Share the proposed model, project standard and records you want to confirm. Keep configuration, current certificate status and installation assumptions with the responsible project reviewers.